Municipal Wastewater Regulation, B.C. Reg. 87/2012
Section 39
Septic tanks
Cite as Municipal Wastewater Regulation, B.C. Reg. 87/2012, s. 39 · last amended October 27, 2025 · read from BC Laws on November 17, 2026
The text
(1) In designing a wastewater facility using a septic tank, a qualified professional must ensure that all of the following requirements are met:
(a) the tank has a hydraulic capacity of at least 2 days' minimum detention time at the design maximum daily flow;
(b) the tank is fitted with an effluent filter, a screen or an equivalent measure to protect pumps and prevent discharge of solids and floatables;
(c) the tank is accessible for pump out.
(2) A director may waive the requirement set out in subsection (1) (b) in respect of small, remote, seasonal discharges to water.
Read the Municipal Wastewater Regulation on BC Laws ↗
Made under Environmental Management Act, SBC 2003, c. 53.