Hazardous Waste Regulation, B.C. Reg. 63/88
Section 31
Performance standards for surface impoundments
Cite as Hazardous Waste Regulation, B.C. Reg. 63/88, s. 31 · last amended July 1, 2026 · read from BC Laws on November 17, 2026
The text
(1) The owner of a surface impoundment must not use a surface impoundment to store or treat ignitable or reactive waste.
(2) The owner of a surface impoundment must design, construct, install and maintain
(a) sufficient depth in the impoundment to ensure a freeboard of 0.5 m at all times,
(b) an inner, fenced buffer area, 20 m wide, immediately surrounding the impoundment, and
(c) devices to immediately shut off flow of hazardous waste to the impoundment in the event of any malfunction of the works.
(3) The owner of a surface impoundment must design, construct, install and maintain an approved liner system
(a) to prevent any migration of wastes out of the impoundment to the adjacent subsurface soil or groundwater during the operating life and closure period,
(b) constructed of impervious materials that prevent wastes from passing into the liner system during the life of the facility, and that
(i) if composed of soil or clay materials, is not less than 0.5 m thick, and
(ii) if synthetic, is at least 1 mm thick,
(c) constructed of materials having appropriate chemical properties, strength and thickness to prevent failure due to
(i) pressure gradients,
(ii) contact with the waste or leachate to which it may be exposed,
(iii) climatic conditions, and
(iv) the stress of installation and daily operations, and
(d) placed on base materials capable of providing support and resistance to pressure gradients above and below the liner system to prevent failure due to compression, uplift or settlement.
(4) The owner of a surface impoundment must design, construct, install and maintain
(a) an approved leak detection system to detect any leaks or migration of liquid through any required liners, and
(b) an approved leachate collection system.
(5) A surface impoundment is in a non-compliance situation, with regard to groundwater quality, when analytical data from upgradient and downgradient groundwater monitoring wells for any parameters or chemical constituents are significantly different using approved statistical methods.
(6) The owner of a surface impoundment must design, construct, install and maintain a system capable of preventing surface water from entering the surface impoundment during a storm with a magnitude that is exceeded, on average, only once in 25 years.
(7) The owner of a surface impoundment must ensure that any discharge of liquid effluent to the environment, to storm sewers or to a municipal or industrial effluent treatment works from the surface impoundment meets the effluent criteria prescribed in Schedule 1.2.
(8) If particulate matter, subject to wind dispersal, is placed in a surface impoundment, the owner must cover or otherwise manage the facility to prevent dispersal by wind.
(9) The owner of a surface impoundment must during closure remove
(a) all stored waste, and
(b) any affected underlying soil to an approved depth.
Read the Hazardous Waste Regulation on BC Laws ↗
Made under Environmental Management Act, SBC 2003, c. 53.