Hazardous Waste Regulation, B.C. Reg. 63/88
Section 21
Performance standards
Cite as Hazardous Waste Regulation, B.C. Reg. 63/88, s. 21 · last amended July 1, 2026 · read from BC Laws on November 17, 2026
The text
(1) The owner of an incinerator or thermal treatment facility must ensure that during operation
(a) the DRE (Equation 1) of the facility is equal to or greater than that specified in Table 1, Table 1 Item Parameter DRE Standards 1 Principal Organic Hazardous Constituents (POHCs) 99.99% 2 Polychlorinated biphenyls (PCBs) 99.9999% 3 Polychlorinated dibenzofurans 99.9999% 4 Polychlorinated dibenzo-p-dioxins 99.9999%
(b) the operating conditions are maintained at levels shown by the demonstration trial referred to in section 20 (2) to be necessary to meet the DRE criteria in Table 1,
(c) the CE (Equation 2) of an incinerator is equal to or greater than 99.9%,
(d) the exhaust emissions meet the emission standards as specified in Schedule 2, and
(e) any discharge of liquid effluent to the environment or to any system of waste disposal operated by a municipality or other public authority which results from the operation of an incinerator or thermal treatment facility meets the effluent standards prescribed in Schedule 1.2.
(2) Section 20 (2) and subsections (1) (a), (b), (c) and (d) do not apply to any industrial utility boiler used for destruction of wastes containing low levels of PCBs or PCP, where
(i) the PCB or PCP content of the waste is less than 500 parts per million,
(ii) the minimum rated capacity of the boiler is 15 MW,
(iii) the boiler is operated at a minimum of 90% of the design steam generating capacity when the waste is fed into the boiler,
(iv) the mass flow rate of the wastes does not exceed 10% of mass flow rate of the fuel into the boiler,
(v) the carbon monoxide concentration in the exhaust gas is not greater than 50 parts per million for a boiler using gaseous or liquid fuel and the carbon monoxide concentration in the exhaust gas for a boiler using solid fuel is not greater than 100 parts per million,
(vi) the excess oxygen must be a minimum of 3% when the wastes are being burned, and
(vii) the concentrations of carbon monoxide and oxygen in the exhaust gas are monitored in an approved manner when the wastes are being burned.
(3) The owner of an incinerator or thermal treatment facility must not allow solid residue to be discharged from it unless
(a) the residue is managed at a hazardous waste management facility in accordance with this regulation, or
(b) the owner demonstrates to the satisfaction of a director in accordance with test protocols or methods approved by a director under section 53 (1) that the residue no longer poses a hazard to human health or to the environment and that the residue is suitable for
(i) disposal to a landfill authorized by a permit, approval under section 15 of the Act, order or waste management plan, or
(ii) some other purpose under an approved management option.
(4) Where an owner has demonstrated to a director in accordance with subsection (3) that a residue no longer poses a hazard to human health or to the environment, the director may, notwithstanding section 39, authorize disposal of the residue to a landfill other than a secure landfill.