Hazardous Waste Regulation, B.C. Reg. 63/88

Section 20

Operational requirements

Cite as Hazardous Waste Regulation, B.C. Reg. 63/88, s. 20 · last amended July 1, 2026 · read from BC Laws on November 17, 2026

The text

(1) Before beginning construction or installation of an incinerator or thermal treatment facility, the owner must (a) provide a detailed engineering description of the incinerator or thermal treatment facility including the following information: (i) manufacturer's name and model number (if available); (ii) type of incinerator or thermal treatment facility; (iii) internal dimension of the incinerator, or thermal treatment facility including the cross sectional area of the process chamber; (iv) description of any auxiliary fuel system including fuel type and feed rate; (v) capacity of air supply and exhaust systems; (vi) description of the automatic waste feed cutoff system or systems; (vii) any stack gas monitoring and pollution control equipment; (viii) nozzle and burner design if the thermal treatment facility is an incinerator; (ix) construction materials; (x) location and description of temperature, pressure and flow sensing and control devices, (b) predict the maximum ambient ground level concentration of emissions from the facility by means of an approved atmospheric dispersion model, and (c) submit a report with the information described in paragraphs (a) and (b) to the district director or a director, as applicable. (2) Before beginning operation of an incinerator or thermal treatment facility, the owner must (a) conduct a demonstration trial in an approved manner to demonstrate the effectiveness of the facility to treat or destroy hazardous waste, and must conduct the trial for a sufficient time under normal operating conditions to obtain (i) a qualitative and quantitative description of the physical, chemical and biological properties of (A) the hazardous waste to be incinerated or thermally treated including all principal organic hazardous constituents (POHCs), (B) any air emissions including all POHCs, products of incomplete combustion (PICs) and parameters listed in Schedule 2, (C) any liquid effluent discharges including all POHCs, PICs and parameters listed in Schedule 1.2, and (D) any solid residues including all POHCs, PICs and trace metals listed in Schedule 2, (ii) a determination of the destruction and removal efficiency (DRE), using Equation 1: DRE = Win − WoutWin x 100% Equation 1 where Win = Mass feed rate of one POHC in the waste feed into the incinerator or thermal treatment facility, Wout = Mass emission rate of the same POHC present in the exhaust emissions, (iii) a determination of the combustion efficiency (CE), using Equation 2: CE = CO 2 CO 2 + CO x 100% Equation 2 where CO 2 = Concentration of carbon dioxide in exhaust emissions, CO = Concentration of carbon monoxide in the exhaust emissions, (iv) a determination of operating conditions including but not limited to (A) the temperature in the combustion zone or the zone of active thermal treatment, (B) the residence time of gases in the combustion zone or the zone of active thermal treatment, and (C) the concentration of excess oxygen in the exhaust emissions whereby the DRE in Equation 1 was determined, and (v) a determination of specific (A) meteorological conditions, and (B) ambient concentrations of POHCs, PICs and other contaminants as approved, and (b) submit a report with the information described in paragraph (a) to the district director or a director, as applicable. (3) The requirement in subsection (2) (a) (iii) does not apply to thermal treatment facilities which generate CO2 from sources other than the combustion process. (4) The owner of an incinerator or thermal treatment facility must (a) provide an alarm system and an automatic cutoff system to stop the hazardous waste feed to the facility when operating conditions specified in the permit are not met, (b) test the automatic cutoff system weekly, and (c) report any malfunction of the automatic cutoff system to the district director or a director, as applicable, within 24 hours after it occurs. (5) The owner of an incinerator or thermal treatment facility must inspect the facility and all associated equipment such as pumps, valves, conveyors, pipes, etc. daily for any leaks, spills, fugitive emissions and signs of tampering or malfunction. (6) Any leaks, spills or fugitive emissions from any incinerator or thermal treatment facility must be controlled by keeping the works sealed or by maintaining the internal pressure lower than the atmospheric pressure. (7) The owner of an incinerator or thermal treatment facility must continuously measure and record for inspection by an officer (a) the temperature in the combustion zone or the zone of active thermal treatment, (b) the waste feed rate, (c) the gas flow rate at the exit from the combustion zone or the zone of active thermal treatment, and (d) carbon monoxide, carbon dioxide and oxygen concentrations in the exhaust gas. (8) The owner of an incinerator or thermal treatment facility must monitor any process emissions for approved parameters at approved intervals. (9) A report of the emissions monitoring including methods and results must be submitted to the district director or a director, as applicable, within 60 days after completion of the emissions monitoring referred to in subsection (8). (10) The owner of an incinerator or thermal treatment facility must monitor the ambient air quality and meteorological conditions using approved methods. (11) A report of the ambient air quality monitoring referred to subsection (10) must be submitted to the district director or a director, as applicable, within 60 days of the end of each calendar quarter.
Read the Hazardous Waste Regulation on BC Laws ↗

Made under Environmental Management Act, SBC 2003, c. 53.