Antisapstain Chemical Waste Control Regulation, B.C. Reg. 300/90

Section 8

Design of antisapstain chemical spray booth systems

Cite as Antisapstain Chemical Waste Control Regulation, B.C. Reg. 300/90, s. 8 · last amended July 8, 2004 · read from BC Laws on November 17, 2026

The text

(1) An antisapstain chemical spray booth system shall have (a) a collection tray that is impervious and that facilitates recycling for re-use of all oversprayed antisapstain chemicals, (b) under both the spray box and collection tray, a containment area that (i) consists of a floor and curb, (ii) is impervious, and (iii) has the capacity to contain all drippings for subsequent recycling or for disposal in accordance with the provisions of the Hazardous Waste Regulation (B.C. Reg. 63/88), and (c) a primary drip area that (i) provides 30 minutes minimum drying time for treated wood immediately following treatment, (ii) has a fixed roof, and (iii) has a system for recycling all drippings for re-use. (2) Emissions to the air from antisapstain chemical application spray booths (a) shall be treated by a demister or an alternative approved by a director and then (i) shall be vented directly to the atmosphere by a stack, the top of which shall be at least 10 metres above the ground and 5 metres above the highest point of the roof of the building which houses the antisapstain chemical spray booth, or (ii) all or part of the treated emission shall be recirculated back to the spray booth, and (b) shall not be combined with any pneumatic stream that conveys chips, sawdust, planer shavings, hog fuel or any other wood residue.
Read the Antisapstain Chemical Waste Control Regulation on BC Laws ↗

Made under Environmental Management Act, SBC 2003, c. 53.