Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 9.25
Testing the atmosphere
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 9.25 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) Except as stated in subsection (7), before a worker enters a confined space, the employer must ensure that the atmosphere in the confined space is tested in accordance with this section and section 9.26.
(2) The pre-entry testing must be
(a) conducted as specified in the written work procedures, and
(b) completed not more than 20 minutes before a worker enters a confined space.
(3) When all workers have vacated the confined space for more than 20 minutes, pre-entry testing, as required by subsection (1), must be repeated.
(4) While a worker is inside a confined space with a moderate or high hazard atmosphere, additional testing must be conducted as necessary to ensure the worker's continuing safety.
(5) Whenever practicable, continuous monitoring of the atmosphere must be done.
(6) If a worker enters a confined space with a moderate or high hazard atmosphere, the employer must continuously monitor the atmosphere if a flammable or explosive atmosphere in excess of 20% of the lower explosive limit could develop.
(7) Pre-entry atmospheric testing is not required in a confined space with a low hazard atmosphere if
(a) the location and control of the space ensures that a more hazardous atmosphere could not inadvertently develop,
(b) such testing is not required to verify the effectiveness of an isolation or other pre-entry control,
(c) prior representative sampling has demonstrated that the atmosphere within the space or group of similar spaces meets the low hazard atmosphere definition, and
(d) the written entry procedures do not require such testing.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.