Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 8.34

Maximum use concentration

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 8.34 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

(1) In subsection (2): “established 8-hour TWA limit” means the 8-hour TWA limit set by the Board for an air contaminant, or if the Board has not set an 8-hour TWA limit for an air contaminant, the TWA limit set by ACGIH for the air contaminant; “established ceiling limit” means a ceiling limit set by the Board for an air contaminant, or if the Board has not set a ceiling limit for an air contaminant, the ceiling limit set by ACGIH for the air contaminant; “established short-term exposure limit” means the short-term exposure limit set by the Board for an air contaminant, or if the Board has not set a short-term exposure limit for an air contaminant, the short-term exposure limit set by ACGIH for the air contaminant. (2) In subsection (3), “maximum use concentration” means the concentration of an air contaminant calculated in one of the following ways: (a) if an established 8-hour TWA limit applies to the air contaminant to which a worker is or might be exposed, by multiplying (i) the established 8-hour TWA limit for the air contaminant, and (ii) the protection factor set out in Table 8-1 that applies to the respirator type that the worker is using; (b) if there is no established 8-hour TWA limit that applies to the air contaminant to which a worker is or might be exposed, by multiplying (i) the established short-term exposure limit for that air contaminant, and (ii) the protection factor set out in Table 8-1 that applies to the respirator type that the worker is using; (c) if there is no established 8-hour TWA limit or short-term exposure limit that applies to the air contaminant to which a worker is or might be exposed, by multiplying (i) the established ceiling limit for that air contaminant, and (ii) the protection factor set out in Table 8-1 that applies to the respirator type that the worker is using. (3) The employer must ensure that a worker does not use a respirator for protection against a concentration of an air contaminant in the workplace that is greater than the maximum use concentration. (4) The protection factor of 1 000 set out in Table 8-1: Respirator protection factors for a hood or helmet facepiece, powered (PAPR), and equipped with a HEPA filter or a sorbent cartridge or canister or both a HEPA filter and a sorbent cartridge or canister applies only if an employer who uses or wishes to use that respirator type has evidence from the manufacturer that demonstrates that (a) the manufacturer has tested that type of respirator, and (b) those tests demonstrate that a respirator of that type has a protection factor of at least 1 000. (5) The protection factor of 25 set out in Table 8-1: Respirator protection factors for a hood or helmet facepiece, powered (PAPR), and equipped with a HEPA filter or a sorbent cartridge or canister or both a HEPA filter and a sorbent cartridge or canister applies if the conditions set out in subsection (4) are not met.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.