Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 7.19
Exposure limits
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 7.19 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) A worker's exposure to ionizing radiation must not exceed any of the following:
(a) an effective dose of 20 mSv over any period of 12 consecutive months;
(b) with respect to exposure to the lens of an eye,
(i) an equivalent dose of 50 mSv over any period of 12 consecutive months that starts on or after December 1, 2021, and
(ii) an equivalent dose of 100 mSv over any period of 60 consecutive months that starts on or after December 1, 2021;
(c) with respect to exposure to the skin, averaged over any 1 cm2 area at a nominal depth of 7 mg/cm2, regardless of the area exposed, an equivalent dose of 500 mSv over any period of 12 consecutive months;
(d) with respect to exposure to the hands and feet, an equivalent dose of 500 mSv over any period of 12 consecutive months.
(2) If a worker declares the worker's pregnancy to the employer, the worker's effective dose of ionizing radiation, for the remainder of the pregnancy, from external and internal sources, must be limited by the employer to the lesser of
(a) 4 mSv, or
(b) the dose limit specified for pregnant workers under the Nuclear Safety and Control Act (Canada).
(3) The employer must ensure that the exposure of workers to ionizing radiation is kept as low as reasonably achievable below the exposure limits.
(4) The employer must ensure that a worker's exposure to non-ionizing radiation does not exceed the exposure limits specified in
(a) for radiofrequency:
(i) Health Canada Safety Code 25, Short-Wave Diathermy Guidelines for Limiting Radiofrequency Exposure, 1983, as amended from time to time;
(ii) Health Canada Safety Code 26, Guidelines on Exposure to Electromagnetic Fields from Magnetic Resonance Clinical Systems, 1987, as amended from time to time;
(iii) Health Canada Safety Code 6, Limits of Human Exposure to Radiofrequency Electromagnetic Fields in the Frequency Range from 3 kHz to 300 GHz, 1999, as amended from time to time, and
(b) for lasers:
(i) ANSI Standard Z136.1-2000, Safe Use of Lasers, as amended from time to time;
(ii) ANSI Standard Z136.2-1997, Safe Use of Optical Fiber Communication Systems Utilizing Laser Diode and LED Sources, as amended from time to time;
(iii) ANSI Standard Z136.3-1996, Safe Use of Lasers in Health Care Facilities, as amended from time to time;
(iv) CSA Standard Z386-01, Laser Safety in Health Care Facilities, as amended from time to time,
except as otherwise determined by the Board.
(5) A worker's exposure to ultraviolet radiation produced by equipment or industrial processes must not exceed the threshold limit values specified in the American Conference of Governmental Industrial Hygienists publication entitled Threshold Limit Values and Biological Exposure Indices, dated 2003, as amended from time to time.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.