(1) The valve on a compressed gas cylinder must be kept closed when the cylinder is empty or not in use. (2) A worker must not stand directly in front of a regulator attached to a compressed gas cylinder when the cylinder valve is being opened. (3) Any valve, regulator or fitting connected to a compressed gas cylinder must be a standard fitting, designed and manufactured for the type of cylinder and compressed gas for which it will be used, and must include provisions for flashback arresters where necessary. (4) Unless a compressed gas cylinder is equipped with an integral valve guard, the valve cover must be in position when the cylinder is not connected for use.