Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 5.1

Definitions

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 5.1 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

In this Part: “8-hour TWA limit” means the time weighted average (TWA) concentration of a substance in air which may not be exceeded over a normal 8 hour work period; “ACGIH” means (a) the American Conference of Governmental Industrial Hygienists publication entitled Threshold Limit Values and Biological Exposure Indices, dated 2002, as amended from time to time, or (b) the American Conference of Governmental Industrial Hygienists publication entitled Documentation of the Threshold Limit Values and Biological Exposure Indices, as amended from time to time; “adverse health effect” means an acute or chronic injury, acute or chronic disease, or death; “approved storage area” means a storage area which meets the requirements of article 4.2.7.5 of the BC Fire Code; “approved storage cabinet” means a flammable liquids storage cabinet which bears a UL or ULC approval label for this purpose or which otherwise meets the requirements of subsection 4.2.10 of the BC Fire Code; “approved storage room” means a room for container storage which meets the requirements of section 4.2.9 of the BC Fire Code; “as low as reasonably achievable” or “ALARA” means, in reference to a substance, that measures must be taken to keep a worker's exposure to a level as low as is reasonably achievable; “bulk shipment” means a shipment of a hazardous product that is contained in any of the following, without intermediate containment or intermediate packaging: (a) a vessel that has a water capacity equal to or greater than 450 litres; (b) a freight container, road vehicle, railway vehicle or portable tank; (c) the hold of a ship; (d) a pipeline; “carcinogen” means a substance or a mixture of substances which is identified as a carcinogen in section 5.57 (1), or (a) causes an increased incidence of benign or malignant neoplasms, or (b) substantially decreases the latency period between exposure and onset of neoplasms in humans, or (c) results in the induction of tumors at a site other than the site of administration in one or more experimental mammalian species as a result of any oral, respiratory, or dermal exposure, or any other exposure, or (d) is metabolized into one or more potential occupational carcinogens by mammals; “CAS registry number” means the identification number assigned to a chemical by the Chemical Abstracts Service, a division of the American Chemical Society; “ceiling limit” means the concentration of a substance in air which may not be exceeded at any time during the work period; “compressed gas” means a substance that meets the criteria for Physical Hazard Class — Gases Under Pressure, Part 7, Subpart 5 of the HPR; “container” includes a bag, barrel, bottle, box, can, cylinder, drum or similar package or receptacle, but does not include a storage tank; “continuous flow emergency shower facility” means a facility capable of delivering water with a spray pattern designed to effectively flush affected areas of the skin; “continuous flow eyewash facility” means a plumbed or portable facility capable of delivering a minimum of 1.5 litres of water per minute (0.33 imp gal per min) with a water pressure not exceeding 175 kPa (25 psi) and with a spray pattern designed to effectively flush both eyes; “drench hose” means a flexible hose connected to a water supply and capable of delivering a minimum of 11.4 litres of water per minute (2.5 imp gal per min), for use to flush the eyes and/or skin; “flammable gas” means a substance that meets the criteria for Physical Hazard Class — Flammable Gases, Part 7, Subpart 2 of the HPR; “fugitive emission” means a gas, liquid, solid, vapour, fume, mist, fog or dust that escapes from process equipment, emission control equipment or from a product where workers may be readily exposed; “hazard information” means information on the proper and safe use, storage and handling of a hazardous product and includes information related to its health and physical hazards; “Hazardous Materials Information Review Act” or “HMIRA” means the Hazardous Materials Information Review Act (Canada); “Hazardous Products Act” or “HPA” means the Hazardous Products Act (Canada); “Hazardous Products Regulations” or “HPR” means the Hazardous Products Regulations (Canada); “hazardous waste” means a hazardous product that is acquired or generated for recycling or recovery or is intended for disposal; “hazardous waste profile sheet” means a written description of the hazardous waste which identifies its hazardous characteristics, hazardous ingredients, and prescribes safe work procedures for handling, storing, using and disposing of the waste; “IARC” means the International Agency for Research on Cancer publication Monographs on the Evaluation of Carcinogenic Risks to Humans, as amended from time to time; “label” means a group of written, printed or graphic information elements that relate to a hazardous product, which group is designed to be affixed to, printed on or attached to the hazardous product or the container in which the hazardous product is packaged; “laboratory sample” means a sample of a hazardous product that is packaged in a container that contains less than 10 kg of the hazardous product and is intended solely to be tested in a laboratory, but does not include a sample that is to be used (a) by the laboratory for testing other products, mixtures, materials or substances, or (b) for educational or demonstration purposes; “manufactured article” means an article that is formed to a specific shape or design during manufacture, the intended use of which, when in that form, is dependent in whole or in part on its shape or design and that, under normal conditions of use, will not release or otherwise cause an individual to be exposed to a hazardous product; “personal eyewash unit” means an eyewash that supplements an emergency eyewash facility by delivering immediate flushing for less than 15 minutes; “portable tank” means a closed container that is designed to be movable while containing liquid, which is equipped with skids, mountings or accessories to facilitate handling of the tank by mechanical means and is not permanently attached to a transporting vehicle, as defined in the BC Fire Code; “product identifier” means, in respect of a hazardous product, the brand name, chemical name, common name, generic name or trade name; “readily available” means, when used in connection with an SDS, present in an appropriate place and in the form of either (a) a physical copy that can be handled, or (b) an electronic copy, that is accessible to a worker at all times; “short-term exposure limit” or “STEL” means the time weighted average (TWA) concentration of a substance in air which may not be exceeded over any 15 minute period, limited to no more than 4 such periods in an 8 hour work shift with at least one hour between any 2 successive 15 minute excursion periods; “significant new data” means new data regarding the hazard presented by a hazardous product that change its classification in a category or subcategory of a hazard class, or result in its classification in another hazard class, or change the ways to protect against the hazard presented by the hazardous product; “storage tank” means a closed container that has a capacity of more than 250 litres (55 imp gal) and is designed to be installed in a fixed location, as defined in the BC Fire Code; “supplementary eyewash facility” means a personal eyewash unit or a drench hose; “supplier label” means a label provided by a supplier that contains the information elements required by the Hazardous Products Act; “tempered” means maintained at temperatures from 15C to 30C (60F to 85F); “temporary” means non-routine work, and does not refer to routine work of short duration; “workplace label” means a label that discloses (a) a product identifier that is identical to that found on the SDS of the corresponding hazardous product, (b) information for the safe handling of the hazardous product that is conveyed in a manner appropriate to the workplace, and (c) that an SDS, if supplied or produced, is available.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.