The text
(1) Unless provided elsewhere in this Regulation, the rated capacity or rated load of a machine or piece of equipment is that specified by the manufacturer of the machine or piece of equipment based on its design.
(2) The rated capacity or rated load must be certified by a professional engineer if
(a) the manufacturer's specification or other acceptable warranty cannot be produced,
(b) the equipment or machine has been modified in a manner which will change its rated capacity or rated load,
(c) wear, corrosion, damage or signs of fatigue are found which may reduce the rated capacity or rated load,
(d) the equipment or machine is used in a manner or for a purpose other than that for which it was originally designed, if the use will change the safe working load, or
(e) in the opinion of the Board, the provision of such certification is deemed necessary.