Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 4.65
Illumination levels
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 4.65 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) Except as otherwise provided in this section and section 4.69, an employer must provide and maintain minimum illumination levels to ensure safe working conditions, safe passage and the identification of hazards or obstructions as follows:
(a) 22 lux (2 fc) in areas of low activity, such as parking lots, building exteriors, outside areas and basement areas housing machinery, but which are not regular task areas;
(b) 54 lux (5 fc) in areas of high activity, such as frequently used walkways and building access and egress points.
(1.1) Cap lamps or other local sources of illumination acceptable to the Board must be used if the light intensity in a work area is less than 22 lux (2 fc) and it is impracticable to provide illumination by any other means.
(2) For tasks which require the ability to distinguish detail an employer must provide and maintain illumination as required by Table 4-1.
(3) For work processes which require lower illumination levels than those specified in subsections (1) and (2), such as photographic darkrooms, fish hatching rooms and poultry catching operations, the employer may use other effective means to ensure the safety of workers.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.