Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 4.62
Handrails on stairways
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 4.62 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) Stairs with more than 4 risers must have continuous handrails on
(a) any open side of the stairway,
(b) one side of enclosed stairways 112 cm (44 in.) or less in width, and
(c) both sides of enclosed stairways over 112 cm (44 in.) wide.
(2) The top of a handrail must be 76 cm to 92 cm (30 in. to 36 in.) above the stair tread, measured vertically from the nose of the tread, and the height must not vary on any flight or succession of flights of stairs.
(3) A handrail on an open side of a stairway must have a midrail located approximately midway between the top of the handrail and the nose of the stair tread.
(4) A handrail must be able to withstand a load of 1.3 kN (300 lbs) applied vertically or horizontally at any point along the handrail.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.