The text

(1) A pit or other opening in a floor, walkway, roof or other area accessible to workers, which is a danger to workers, must be securely covered with a cover of adequate size and strength or guarded by fixed or movable guardrails, which must be identified as such and kept in place except when necessarily removed to work in the opening or pit. (2) If compliance with subsection (1) is not practicable for a vehicle service pit, the area around the perimeter of the pit must be marked in a high visibility colour extending back at least 1 m (3.3 ft.) from the edge of the pit, and the marking coating or material must provide a skid resistant surface. (3) Subsection (1) does not apply to a trap door in a performance stage or scenic unit that will be visible to the audience during a rehearsal or performance, provided that effective measures are taken to protect performers and other workers from injury. (4) If a worker must enter an area not normally accessible and that has openings that are a danger, such openings must be guarded or personal fall protection must be used while the worker is in the area.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.