Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 4.55

Guardrail locations

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 4.55 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

An area accessible to workers must have guards or guardrails installed in any of the following circumstances: (a) if a raised floor, open-sided floor, mezzanine, gallery, balcony, work platform, ramp, walkway, or runway is 122 cm (4 ft.) or more above the adjacent floor or grade level; (b) on both sides of any walkway over or adjacent to any substance which is a hazard if a worker fell in, or on it, or which is over machinery or work areas; (c) around the perimeter of any open container or containment area such as an open vat, bin, tank or pit which is 122 cm (4 ft.) or more in depth and which has sides that do not extend at least as high as required for a guardrail above the adjacent grade or work surface; (d) if a stairway ends in direct proximity to dangerous traffic or other hazard to prevent inadvertent entry into the dangerous area.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.