Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 34.13

Temporary anchors

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 34.13 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

(1) In this section, “temporary anchor” means an anchor that is removed from service immediately after use. (2) A temporary anchor for a rope access system must have an ultimate load capacity, in any direction in which the load may be applied, of at least 12 kN (2 700 lbf) for each person connected to the temporary anchor.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.