Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 31.22

Sealing and fit testing

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 31.22 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

(1) Firefighters who use a self-contained breathing apparatus must be clean shaven to ensure that the mask forms a positive seal against the face. (2) Fit tests must be performed in accordance with procedures in CSA Standard CAN/CSA-Z94.4-02, Selection, Use, and Care of Respirators. (2.1) A fit test must be carried out (a) before initial use of a respirator, (b) at least once a year, (c) whenever there is a change in respirator facepiece, including the brand, model, and size, and (d) whenever changes to the user's physical condition could affect the respirator fit. (3) Personal protective equipment that is worn with self-contained breathing apparatus and might interfere with a proper fit must be worn during the fit test. (4) Only corrective eyewear designed for use with self-contained breathing apparatus may be worn.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.