Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 30.26
Biological agents and human pathogens
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 30.26 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) Adequate facilities must be readily available for personal decontamination of workers who come in contact with a biological agent.
(2) Work procedures which may generate aerosols containing a biological agent must be performed only under controlled conditions designed to minimize creation of the aerosols and prevent worker exposure to them.
(3) For Risk Group 2 human pathogens, sealed centrifuge safety heads, rotors or trunnion cups must be opened within a fume hood or biological safety cabinet unless there is a means of visually determining, by use of clear safety caps or other effective means, that no breakage or leaking has occurred.
(4) For Risk Group 3 human pathogens, sealed centrifuge safety heads, rotors or trunnion cups must be loaded and unloaded within a biological safety cabinet.
(5) Work involving Risk Group 4 human pathogens must be done as required by the Laboratory Biosafety Guidelines 3rd edition, 2004, issued by the Public Health Agency of Canada.
(6) In this section:
“Risk Group 2 human pathogens” mean the human pathogens that are classified by the Public Health Agency of Canada as Risk Group 2 human pathogens;
“Risk Group 3 human pathogens” mean the human pathogens that are classified by the Public Health Agency of Canada as Risk Group 3 human pathogens;
“Risk Group 4 human pathogens” mean the human pathogens that are classified by the Public Health Agency of Canada as Risk Group 4 human pathogens.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.