Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 26.49

Skyline rigging

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 26.49 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

(1) When rigged in a backspar, a skyline must be anchored no more than 8° off-line from the rearward projection of the skyline. (2) If a suitable anchor cannot be found to comply with subsection (1), another suitable anchor may be used provided that the backspar is stabilized by extra guylines. (3) The rearward projection of the skyline must (a) not be considered a guyline, and (b) not make an angle greater than 50° measured from the horizontal as it leaves the backspar unless approved by a professional engineer. (4) The method used to support a skyline at a backspar or intermediate spar must provide adequate support and protection for the line. (5) A skyline must not be fastened directly to a backspar.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.