Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 24.64

Intakes, pipes and tunnels

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 24.64 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

(1) If a diver is required to approach or enter the intake of any pipe, tunnel, duct, or similar installation the diver must be provided with the means to distinguish the specific intake from any others in the vicinity. (2) A diver must not enter the water until flow through the intake is stopped and the intake mechanism is locked out, and the flow must not be restarted until the diver has left the water. (3) If divers are required to approach a hazardous mechanism, a pressure differential structure, or the intake of any pipe, tunnel, duct or similar installation, the divers must use only surface-tethered diving equipment with effective two-way voice communication with the surface; if required to enter, they must use only surface supplied diving equipment with effective two-way voice communication with the surface.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.