Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 24.57
Diving system procedures
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 24.57 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) The diving supervisor must ensure that a lock-out diving operation is not conducted from a submersible unless
(a) the submersible is negatively buoyant on the bottom or positively secured to the work site,
(b) the diving supervisor is on board the submersible and present in the one atmosphere chamber during the lock-out operation, and
(c) a standby diver is monitoring the lock-out operation from the submersible's compression chamber and is dressed and equipped to immediately carry out rescue operations in the event of an emergency.
(2) The diving supervisor must ensure that lock-out submersible and atmospheric diving system operations are not conducted unless
(a) a backup unit with sufficient depth capabilities to effect a rescue is available for use in the event of an emergency,
(b) the on-board life-support system of the LOS is capable of sustaining life for a period of time that would enable the backup unit to reach the site of the diving operation and effect rescue, and
(c) a breathing mixture is provided that will meet the needs of the occupants for at least 48 hours.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.