Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 24.46

Manifolds and fittings

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 24.46 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

(1) The manifold system must be provided with (a) a primary and a reserve air supply capable of being isolated from each other, and (b) piping of a diameter which ensures an adequate flow of gas to the diver(s). (2) The reserve supply must provide a sufficient quantity of breathing mixture to enable the diver to return to the surface and undergo all "in water" decompression. (3) If there is no voice communication with the diver, each surface supplied air system must be equipped with an audible low pressure alarm situated so that it can be heard by the diving supervisor and the diver's tender.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.