Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 23.63

Guylines

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 23.63 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

(1) Derrick guylines must be secured to adequate ground anchors. (2) Derrick guylines and ground anchors must be installed according to the requirements of the manufacturer, a professional engineer, or the American Petroleum Institute Recommended Practice RP 4G-1992, Maintenance and Use of Drilling and Well Servicing Structures, First Edition, January 1, 1992. (3) Permanent ground anchors must be designed and installed so they will be effective all year round. (4) Temporary ground anchors must be pull tested before initial use and, if they continue to be used, tested annually and whenever they may have been affected by seasonal changes. (5) The manufacturer's specifications for the correct number of guylines and spacing must be legibly marked on a plate affixed to the derrick, or on a specification sheet posted at the rig. (6) The prime contractor or owner must ensure that documentation is available on site showing that ground anchors meet the requirements of this Part, and that such documentation is signed by the person responsible for the adequacy of the anchors.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.