Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 23.47

Guardrails

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 23.47 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

(1) Guardrails installed on the walkways and platforms of mud tanks must have (a) a horizontal top rail not less than 90 cm (36 in) nor more than 1.1 m (42 in) high, and (b) posts or uprights spaced not more than 3 m (10 ft) apart. (2) Guardrails must be installed on (a) the outer perimeter of all mud tank hinged wing platforms or walkways, and (b) both sides of walkways located over mud tanks. (3) Wire rope of not less than 10 mm (3/8 in) diameter, or chain of equivalent strength, may be substituted for guardrails on mud tank walkways if the ropes or chains are rigged and maintained at the required height and kept taut. (4) Floor openings, elevated walkways and platforms must have toeboards meeting the requirements of Part 4 (General Conditions) if the height exceeds 3 m (10 ft) above grade.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.