Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 23.41
Stabbing boards
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 23.41 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) A stabbing board must be used by a worker located above the derrick floor during the running of casing or tubing, or well servicing operations.
(2) A wooden stabbing board must
(a) be fitted with expanded metal or wire rope fastened to the underside and along the full length of the board,
(b) have each end of the board secured to the derrick by a wire rope of not less than 13 mm (1/2 in) diameter, or chain of at least equivalent strength, and
(c) be at least 30 cm (12 in) wide.
(3) A metal platform of equal width and strength may be used in place of a wooden stabbing board.
(4) At the stabbing board, a personal fall protection system must be attached to
(a) wire rope with a breaking strength of not less than 40 kN (9 000 lbs) stretched across the derrick at a location approximately 2 m (7 ft) above the stabbing board,
(b) a cross-member of the derrick structure at a point approximately 2 m (7 ft) above the stabbing board, or
(c) a solid support secured across the derrick at a location approximately 2 m (7 ft) above the stabbing board.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.