The text
(1) The employer must ensure that each underground working supervisor is provided with current development plans for the underground working supervisor's assigned area of responsibility which indicate the size, inclination and length of all development openings and drill holes, and points where openings are or will be within 8 m (25 ft) of a breakthrough.
(2) If an active heading is within 8 m (25 ft) of another underground opening or drill hole, the underground working supervisor must, before any round is fired,
(a) make a thorough examination of other underground openings, drill hole collars, or the nearest point of intersection,
(b) ensure that the heading can be safely advanced, and
(c) ensure that access to the nearest point of intersection with the other opening or drill hole is guarded.
(2.1) The underground working supervisor must ensure that all findings, and any corrective actions taken, under subsection (2) are documented in the Underground Record referred to in section 22.7.
(3) If 2 headings are expected to connect and are within 8 m (25 ft) of connecting, all work must cease in one of the headings, and all previously blasted holes must be examined for remnants of explosives.
Read the Occupational Health and Safety Regulation on BC Laws ↗