Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 22.54

Fire prevention and control

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 22.54 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

The employer must ensure that (a) sufficient suitable fire extinguishers or other systems of fire control are available at any underground location where a fire may occur, and that automatic systems are installed in shops and lunch rooms, (b) Repealed. [B.C. Reg. 312/2003, App. E, s. 21 (a).] (c) combustible liquids with a flash point below 52°C (126°F), flammable liquids, oil and grease used in an underground working are transported and stored only in metal containers or receptacles or in portable plastic containers approved for petroleum fuels, and when stored underground, unless in an approved enclosure, are restricted to a quantity sufficient for the current day's work, (d) any equipment repair or refueling depot is not located underground unless written permission has been obtained from the Board, and (e) workers do not build, start, or maintain a fire in an underground working. (f) Repealed. [B.C. Reg. 312/2003, App. E, s. 21 (d).]
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.