Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 22.25

Duct air testing

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 22.25 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

(1) Duct air velocities must be measured at least once a week and any deficiencies must be corrected. (2) Testing must take place (a) within 9 m (30 ft) of the main duct inlet and any branch inlets, (b) at the auxiliary fan duct outlet, (c) 6 m to 15 m (20 ft to 50 ft) from the portal fan, and (d) at any other location or interval as directed by an officer. (3) The results and observations of all testing and any corrective action taken must be recorded in the Underground Record.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.