(1) All electrical equipment, including switches, connectors, wiring and cables must be designed, installed and weatherproofed to ensure the integrity of the electric components under all operating conditions. (2) An electrically powered raise climber must not be operated at a potential of more than 750 volts, and must be protected by a ground fault system. (3) The operating controls and electrical panels of an electrically driven raise climber must be capable of being locked out to prevent unauthorized operation. (4) Every raise climber must be equipped with a suitable fire extinguisher.