Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 21.63
Testing electric blasting circuits
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 21.63 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) The blaster of record must ensure that each electric blasting circuit is tested before firing.
(2) In seismic blasting, the blaster of record must ensure that each electric blasting circuit is tested after the blast hole is loaded with explosives and before a plug is placed into the hole.
(3) If the electric blasting circuit is equipped with an electric detonator or electric igniter, the blaster of record must ensure that before firing,
(a) the resistance of the circuit is measured using a blasting galvanometer or another instrument specifically designed for testing electric detonators and circuits containing them, and
(b) the resistance is recorded in the blasting log.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.