Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 21.61
Radio frequency precautions
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 21.61 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) If the electric blasting circuit is equipped with an electric detonator, minimum distances from radio frequency transmitters as detailed in Institute of Makers of Explosives, Safety Guide for the Prevention of Radio Frequency Radiation Hazards in the Use of Commercial Electric Detonators (Blasting Caps) Safety Library Publication No. 20, December 2011 as amended from time to time, must be maintained.
(1.1) If the blasting system is equipped with an electronic detonator or electric igniter, minimum distances from radio frequency transmitters as recommended by the manufacturer must be maintained.
(2) If the minimum distance has not otherwise been determined, electric blasting circuits are not permitted within
(a) 100 m (330 ft) of a CB radio or other mobile or portable radio frequency transmitter, and
(b) 1 000 m (3 300 ft) of an AM or FM radio, TV, or other fixed radio frequency transmitter.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.