Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 20.95
Water accumulation
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 20.95 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) Water must not be allowed to accumulate in an excavation if it might affect the stability of the excavation or might endanger workers.
(2) Erosion of slopes by surface water must be prevented if workers may be endangered. Table 20-1: Trench support structures
Size and spacing of members1 (metric figures) Uprights Walers Cross Braces Trench depth
(metres) Minimum
dimensions
(millimetres)2 Maximum
spacing
(metres) Minimum
dimensions
(millimetres)2 Maximum
vertical
spacing
(metres) Width of trench
(metres) Maximum spacing (metres) Up to 1.8 1.8-3.7 Vertical Horizontal Minimum dimensions
(millimetres)2 Type A: Hard and solid soil 1.2-33 38 x 235 1.8 89 x 140 1.2 89 x 89 140 x 140 1.2 1.8 3-4.6 38 x 235 1.2 140 x 140 1.2 89 x 140 140 x 191 1.2 1.8 4.6-6 38 x 235 Close tight 140 x 140 1.2 140 x 191 191 x 191 1.2 1.8 Type B: Soil likely to crack or crumble 1.2-33 38 x 235 1.2 89 x 140 1.2 89 x 140 140 x 140 1.2 1.8 3-4.6 38 x 235 0.9 140 x 191 1.2 140 x 140 140 x 191 1.2 1.8 4.6-6 38 x 235 Close tight 140 x 191 1.2 140 x 191 191 x 191 1.2 1.8 Type C: Soft, sandy, filled or loose soil 1.2-33 38 x 235 Close tight 140 x 191 1.2 140 x 140 140 x 191 1.2 1.8 3-4.6 38 x 235 Close tight 191 x 191 1.2 140 x 191 191 x 191 1.2 1.8 4.6-6 38 x 235 Close tight 191 x 241 1.2 140 x 191 191 x 241 1.2 1.8 Size and spacing of members1 (imperial figures) Uprights Walers Cross Braces Trench depth
(feet) Minimum dimensions
(inches)2 Maximum spacing
(feet) Minimum
dimensions
(inches)2 Maximum
vertical
spacing
(feet) Width of trench
(feet) Maximum spacing
(feet) Up to 6 6-12 Vertical Horizontal Minimum dimensions
(inches)2 Type A: Hard and solid soil 4-103 2 x 10 6 4 x 64 4 4 x 4 6 x 6 4 6 10-15 2 x 10 4 6 x 6 4 4 x 6 6 x 8 4 6 15-20 2 x 10 Close tight 6 x 6 4 6 x 8 8 x 8 4 6 Type B: Soil likely to crack or crumble 4-103 2 x 10 4 4 x 6 4 4 x 6 6 x 6 4 6 10-15 2 x 10 3 6 x 8 4 6 x 6 6 x 8 4 6 15-20 2 x 10 Close tight 6 x 8 4 6 x 8 8 x 8 4 6 Type C: Soft, sandy, filled or loose soil 4-103 2 x 10 Close tight 6 x 8 4 6 x 6 6 x 8 4 6 10-15 2 x 10 Close tight 8 x 8 4 6 x 8 8 x 8 4 6 15-20 2 x 10 Close tight 8 x 10 4 6 x 8 8 x 10 4 6 1 The dimensions shown are minimum and must be increased if necessary to meet job conditions. 2 The dimensions of members in millimetres are actual dimensions for surfaced dry materials. The dimensions in inches are the nominal values for surfaced dry materials. 3 Trenches less than 1.2 m (4 ft) deep must be shored when hazardous ground movement may be expected, as in ground subject to hydrostatic pressure or vibration. 4 Walers may be omitted in trenches not exceeding 2.4 m (8 ft) in depth provided that it has been confirmed that the soil is sufficiently hard and solid to safely permit waler deletion, and provided that the trench is not in proximity to previously excavated ground.
Figure 20-1: Sloping in lieu of shoring
Case 1 (trench or bulk excavation) — maximum slope of excavated face, shown as line AB, in hard and solid soil is 3 horizontal to 4 vertical.
Case 2 (trench or bulk excavation) — maximum height of vertical portion, shown as line AB is 1.2 metres (4 feet).
For Case 2 (trench or bulk excavation) the maximum permissible slope of the excavated face BC for the corresponding height of the lower vertical cut AB is as follows: Height of line AB Maximum slope of line BC
(in hard and solid soil) centimetres feet up to 30 up to 1 1 horizontal (H) to 1 vertical (V) 30 to 60 1 to 2 3H to 2V 60 to 90 2 to 3 2H to 1V 90 to 120 3 to 4 3H to 1V
Figure 20-2: Benching in lieu of shoring
Figure 20-3: Combined supporting and sloping
Shoring must be adequate for excavation depth H.
Depth H cannot exceed 6 metres (20 feet).
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.