Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 20.47
Equipment inspection
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 20.47 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) A mast must be inspected in accordance with good engineering practice at intervals not exceeding 12 months, repaired as necessary, and certified safe for use by a professional engineer, the manufacturer or the manufacturer's authorized agent.
(2) A concrete pump and placing boom must be inspected in accordance with good engineering practice at intervals not exceeding 12 months to ensure that they meet
(a) the manufacturer's specifications,
(b) the requirements of the applicable standard referred to in section 20.26.3, and
(c) the requirements of this Regulation.
(3) Without limiting subsection (2), an inspection under that subsection must include an inspection of the structural, mechanical and control system components of the concrete pump and placing boom.
(4) On and after January 1, 2021, a concrete pump and placing boom must not be used after an inspection under subsection (2) unless a professional engineer certifies that, on the basis of that inspection, they are safe for use.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.