Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 20.37

Agitator guarding

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 20.37 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

(1) Concrete pump agitator guarding must be maintained to the pump manufacturer's specifications, with reasonable allowance for wear. (2) Bent bars in a concrete pump agitator grill guard must be repaired. (3) Concrete pump grill bar spacing may be increased to a maximum bar spacing of 8 cm (3 1/4 in) when pumping concrete mixes with a slump of 5 cm (2 in) or less and provided specific instructions are given to the crew regarding the hazard present due to the larger openings in the grill guard. (4) The distance from the grill bars to the concrete pump's agitator must be at least 7.5 cm (3 in). (5) A concrete pump agitator grill guard must be hinged or bolted in place. (6) A person must not stand on the grill when the concrete pump or agitator is running.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.