Occupational Health and Safety Regulation, B.C. Reg. 296/97
Section 20.32
Hydraulic cylinders
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 20.32 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
(1) Hydraulic cylinders on a concrete pump, placing boom and mast must have pressure relief valves to prevent cylinder and boom damage due to excess pressure.
(2) Hydraulic holding valves must be used on a concrete pump, placing boom or mast if hydraulic hose or coupling failure could result in uncontrolled movement of mechanisms.
Read the Occupational Health and Safety Regulation on BC Laws ↗
Made under Workers Compensation Act, RSBC 2019, c. 1.