Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 19.1

Definitions

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 19.1 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

In this Part: “apprentice utility arborist” means a worker who is not yet a certified utility arborist but has completed a course of instruction recognized by the certifying authority; “approved” as applied to electrical equipment, means that the equipment meets the requirements of the Electrical Safety Regulation; “certified utility arborist” means a person who has completed a course of instruction, has a minimum of 1 200 hours of practical experience and is certified by an authority acceptable to the Board; “conductor” means a wire, cable or other metal component installed for the purpose of conveying electric current from one piece of equipment to another or to ground; “control system” means a manual, remote, automatic or partially automatic system for controlling the operation of equipment; “damp location” means an exterior or interior location that is subject to condensation of moisture in, on or adjacent to portable electrical equipment; “electrical equipment” includes machinery, plant, works, wires, pipes, poles, conduits, apparatus, appliances and equipment, designed or used, or intended for use, for or in connection with generation, transmission, supply, distribution or use of electrical energy for any purpose; “electrical worker” means a person who meets the requirements of the Electrical Safety Regulation for installing, altering or maintaining electrical equipment; “electrofishing” means the capture or control of fish by the use of electrical equipment; “exposed”, as applied to electrical equipment or conductors, means that the conductor or a part of the equipment is (a) electrically connected to a source of voltage difference or electrically charged to have a voltage different from that of earth, (b) not guarded or insulated in an approved manner, and (c) in a location where a person or any tool, equipment or material the person is touching or using might come closer than a safe distance away from the conductor or part; “hardwired” means the electrical connection of components within a system by means of electrical conductors so that the only way the system can be modified is by changing the connections; “high voltage” means a potential difference (voltage) of more than 750 volts between conductors or between a conductor and ground; “isolated” means that normal sources of energy have been disconnected by opening and securing all associated switches, and that mechanical equipment has been rendered and secured non-operative by disconnecting, stopping, depressurizing, draining, venting or other effective means; “low voltage” means a potential difference (voltage) from 31 to 750 volts inclusive, between conductors or between a conductor and ground; “mimic display” means a symbolic representation of the configuration and status of all or part of a power system, complete with device designations; “power system” means all plant and equipment essential to the generation, transmission or distribution of electricity, including any plant or equipment that is out of service, being constructed or being installed; “safety protection guarantee” means an assurance that a power system or part of the power system is isolated and will remain isolated; “safety watcher” means a qualified person whose sole task is to observe the activity when equipment, vegetation or material will be moved relative to energized electrical equipment or conductors, and signal in a clear and predetermined manner to stop the movement whenever contact with electrical equipment, conductors or guarding appears probable, or whenever conditions prevent the watcher from having a clear view of the movement relative to the electrical equipment; “service room” means a room or space in a building provided to accommodate building service equipment, and meeting the requirements of the BC Building Code or other applicable legislation; “vault” means an isolated enclosure, either above or below ground, with fire-resisting walls, ceilings and floors for the purpose of housing transformers and other electrical equipment; “wet location” means an exterior or interior location in which uncontrolled liquid may drip, splash or flow on or against portable electrical equipment.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.