Wire rope rejection criteria
Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 15.25 · last amended September 1, 2027 · read from BC Laws on November 17, 2026
The text
Wire rope must be permanently removed from service if
(a) in running wire ropes, there are 6 or more randomly distributed wires broken in one rope lay or 3 or more wires are broken in one strand in one lay,
(b) in stationary wire ropes, such as guylines, there are 3 or more broken wires in one lay in sections between end connections, or more than one broken wire within one lay of an end connection,
(c) wear, or the effects of corrosion, exceed 1/3 of the original diameter of outside individual wires,
(d) there is evidence of kinking, bird-caging or any other damage resulting in distortion of the rope structure,
(e) there is evidence of heat or arc damage, or
(f) there are reductions of normal rope diameter, from any cause, in excess of
(i) 0.4 mm (1/64 in.) for diameters up to and including 8 mm (5/16 in.),
(ii) 1 mm (3/64 in.) for diameters greater than 8 mm (5/16 in.) up to and including 19 mm (3/4 in.),
(iii) 2 mm (1/16 in.) for diameters greater than 19 mm (3/4 in.) up to and including 29 mm (1 1/8 in.), or
(iv) 3 mm (3/32 in.) for diameters greater than 29 mm (1 1/8 in.).