(1) A tower crane must have a fixed ladder installed in or on the mast to provide access to the jib and crown of the crane.
(2) The ladder under subsection (1) must meet the following requirements:
(a) the ladder must be able to support two 1.1 kN (250 lbs.) point loads between any two consecutive points where the ladder is attached to the crane;
(b) there must be a minimum horizontal distance of 15 cm (6 in.) between the rungs and the object to which the ladder is attached;
(c) landing platforms must be provided at least every 9 m (30 ft.) on the ladder;
(d) each section of the ladder must be offset horizontally from adjacent sections or the landing platforms must have trap doors;
(e) if a section of the ladder has a climb exceeding 6 m (20 ft.) in length, that section of ladder must have a ladder safety cage 68 cm to 76 cm (27 in. to 30 in.) in diameter or a ladder safety device must be used.
(3) Each tower crane jib must have a continuous walkway from the mast to the tip.
(4) The walkway referred to in subsection (3) must meet the following requirements:
(a) the walkway must be at least 30 cm (12 in.) wide and constructed with a non-skid surface;
(b) a handline, which is approximately 1 m (39 in.) above the level of the walkway, and a midline must be provided on both sides of the walkway not more than 30 cm (12 in.) out from the edge of the walkway and supported at intervals not exceeding 3 m (10 ft.);
(c) the handline and midline referred to in paragraph (b) must be wire rope of at least 1 cm (3/8 in.) diameter;
(d) if it is not practicable to provide handlines in accordance with paragraph (b), alternative means of fall protection, such as a horizontal lifeline system, must be provided in accordance with the requirements of Part 11 (Fall Protection) and must be set out in the fall protection plan.
(5) If, due to the design or size of the tower crane, it is not practicable to meet the requirements set out in subsections (1) to (4), alternative safe means of access must be provided.
(6) The climbing space of a tower crane mast must be clear of protruding objects and must provide a safe and unobstructed passage.
(7) A written fall protection plan, which addresses the requirements of fall protection when a person is operating, inspecting, servicing and maintaining the tower crane, must be developed and implemented.
Read the Occupational Health and Safety Regulation on BC Laws ↗