(1) Subject to subsection (4), before the erection of a tower crane, the structural components of the crane must be
(a) inspected to determine their integrity by a qualified person using non-destructive testing (NDT) methods meeting the requirements of the Canadian General Standards Board (CGSB), and
(b) certified by a professional engineer as safe for use after the inspection in paragraph (a) and any necessary repairs.
(2) If a tower crane remains erected at a workplace for more than 12 months,
(a) its structural components must be inspected to determine their integrity by a qualified person using NDT methods meeting the requirements of the CGSB, and
(b) after the inspection required by paragraph (a), the crane, including any necessary repairs, must be certified by a professional engineer as safe for use.
(3) If a tower crane is scheduled to be dismantled within 15 months of its being erected, subsection (2) does not apply provided that a visual inspection, conducted 12 months after erection of the crane and supervised by a professional engineer, shows no evidence of cracking or other structural weakness.
(4) A self erecting tower crane must be
(a) inspected visually by a qualified person each time it is erected, and
(b) inspected and certified under subsection (1) at least once every 12 months.
(5) Subsection (3) does not apply to a self erecting tower crane.