The text

(1) A transfer, dry-to-dry, or fully enclosed refrigerated system must have an effective exhaust ventilation system which operates whenever the loading door is open to create an airflow into the door opening of at least 50 cm/sec (100 fpm) averaged across the face of the opening, and which maintains the concentration of solvent vapour in the workplace below the applicable exposure limits. (2) A fully enclosed refrigerated system is exempt from the requirements of subsection (1) if workers are not exposed to levels of solvent vapours above 50% of the applicable exposure limits.
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.