Occupational Health and Safety Regulation, B.C. Reg. 296/97

Section 11.6

Anchors

Cite as Occupational Health and Safety Regulation, B.C. Reg. 296/97, s. 11.6 · last amended September 1, 2027 · read from BC Laws on November 17, 2026

The text

(1) In a temporary fall restraint system, an anchor for a personal fall protection system must have an ultimate load capacity in any direction in which a load may be applied of at least (a) 3.5 kN (800 lbs), or (b) four times the weight of the worker to be connected to the system. (2) Each personal fall protection system that is connected to an anchor must be secured to an independent attachment point. (3) In a temporary fall arrest system, an anchor for a personal fall protection system must have an ultimate load capacity in any direction required to resist a fall of at least (a) 22 kN (5 000 lbs), or (b) two times the maximum arrest force. (4) A permanent anchor for a personal fall protection system must have an ultimate load capacity in any direction required to resist a fall of at least 22 kN (5 000 lbs).
Read the Occupational Health and Safety Regulation on BC Laws ↗

Made under Workers Compensation Act, RSBC 2019, c. 1.