Drilling and Production Regulation, B.C. Reg. 282/2010

Section 58

Production test of oil wells

Cite as Drilling and Production Regulation, B.C. Reg. 282/2010, s. 58 · last amended April 1, 2025 · read from BC Laws on November 17, 2026

The text

(1) A permit holder must conduct at least 2 production quantity tests per month on each oil well whose production quantity is delivered to a proration battery. (2) A production quantity test referred to in subsection (1) must (a) measure the quantities of petroleum, water and natural gas produced, (b) be at least 22 hours in duration, (c) be adequately spaced throughout the month, and (d) allow sufficient purge time before the test to ensure that liquids from a previous quantity test are replaced by the fluids from the new well to be tested. (3) A permit holder must keep records of production quantity tests conducted, and the records must include the following, as applicable: (a) quantity test date; (b) duration of the quantity test in hours; (c) opening and closing meter readings; (d) meter factor; (e) percent of basic sediment and water; (f) quantities of petroleum, water and natural gas produced during the quantity test; (g) average separator pressure over the time duration of the quantity test; (h) net gas oil ratio; (i) petroleum density. (4) To calculate the monthly estimated oil well quantity production that is to be reported for each oil well producing to a proration battery, a permit holder must use the test-to-test method of calculation.
Read the Drilling and Production Regulation on BC Laws ↗

Made under Energy Resource Activities Act, SBC 2008, c. 36.