Drilling and Production Regulation, B.C. Reg. 282/2010
Section 45
Fire precautions
Cite as Drilling and Production Regulation, B.C. Reg. 282/2010, s. 45 · last amended April 1, 2025 · read from BC Laws on November 17, 2026
The text
(1) A well permit holder must ensure that, if engines are located at a wellsite, suitable safeguards are in place and tested to prevent a fire or explosion in the event of a release of flammable liquids or ignitable vapours.
(2) Except where gasoline or liquid fuel is held in fuel tanks actually connected to operating equipment, a well permit holder must not store gasoline or liquid fuel within 25 m of a well, and must ensure that drainage of gasoline or liquid fuel from the places where it is stored is in a direction away from a well location.
(3) If a pressure relieving device is installed on a pressure vessel at a facility, the permit holder must ensure
(a) that the device is connected by suitable piping to a tank if production is in the liquid phase,
(b) that the device is connected to a flare system, if a flare system exists at the facility, or
(c) that a system of controls is installed to ensure safe operation and minimize venting.
(4) A person carrying out an energy resource activity must not smoke within 25 m of any well or facility.
Read the Drilling and Production Regulation on BC Laws ↗
Made under Energy Resource Activities Act, SBC 2008, c. 36.