Gasoline Vapour Control Regulation, B.C. Reg. 226/95
Section 4
Cargo tanker requirements
Cite as Gasoline Vapour Control Regulation, B.C. Reg. 226/95, s. 4 · last amended October 28, 2019 · read from BC Laws on November 17, 2026
The text
(1) Effective May 1, 1996, every owner of a cargo tanker with over 21 000 litres capacity that is used to deliver gasoline
(a) from a terminal required by this regulation to be equipped with a vapour control system, or
(b) to any retail service station, card lock or fleet refuelling station in the Lower Fraser Valley which is equipped with 2 or more nozzles and which does not have an exemption tag attached to its fill pipe
must equip the cargo tanker with a vapour balancing system.
(2) Effective May 1, 1997, a person must not deliver more than 2 000 litres of gasoline from a cargo tanker to a gasoline storage tank located at a retail service station, card lock or fleet refuelling station in the Lower Fraser Valley that is equipped with 2 or more gasoline nozzles unless the storage tank has
(a) a vapour balancing system, or
(b) an exemption tag attached to its fill pipe.
(3) Subsection (2) does not apply to deliveries made from a cargo tanker having a capacity of 21 000 litres or less.
(4) Effective May 1, 1996, every owner of a cargo tanker required by subsection (1) to be equipped with a vapour balancing system must, at least once in every 12 months, pressure test and vacuum test the cargo tanker, including all vapour balancing system hoses and fittings, for vapour tightness in accordance with the CGSB Standard.
(5) If a cargo tanker fails either the pressure test or the vacuum test, the owner must, within 48 hours after it has failed the test, remove the cargo tanker from service until it has been repaired in accordance with the CGSB Standard.
(6) Every owner of a cargo tanker that passes the pressure test and vacuum test must identify the most recent testing date by marking the date of the vacuum and pressure tests in a visible location on the front right side of the cargo tanker.
(7) The testing dates must be indicated, in bold print of a minimum 50mm size, with references to "vacuum test" or "vacuum" and "pressure test" or "pressure", and the corresponding testing dates in a day/month/year format.
(8) Every owner of a cargo tanker that is required to have a vapour balancing system must ensure the proper operation of the system and, without restricting the foregoing, must do all of the following:
(a) provide adequate training to cargo tanker operators respecting the use of the vapour balancing system, including when the operator is prohibited by this regulation from transferring gasoline;
(b) provide written operating procedures to cargo tanker operators;
(c) provide written standard maintenance procedures to employees maintaining the system;
(d) ensure that whenever fuel is transferred between a facility and a cargo tanker, both of which are equipped with a vapour control system, the vapour connections are completed before making the liquid connections by using the sequence recommended in the CGSB Standard;
(e) conduct periodic visual checks of the cargo tanker vapour balancing system to ensure that it is in good working order;
(f) ensure the proper use of the vapour control system by cargo tanker operators.