Asphalt Plant Regulation, B.C. Reg. 217/97
Section 5
Emission limits and operating parameters
Cite as Asphalt Plant Regulation, B.C. Reg. 217/97, s. 5 · last amended October 28, 2019 · read from BC Laws on November 17, 2026
The text
(1) The owner or operator of a hot-in-place asphalt recycling plant must not permit the discharge of emissions which exceed the concentration limits in Column 2 or the production limits in Column 3 set out opposite the parameter in Column 1 of Schedule A.
(2) If the plant uses direct fired infrared heating, it must comply with the following operating parameters:
(a) the afterburner combustion temperature must not be less than 650C (1 200F);
(b) the temperature of each afterburner unit must be displayed so that it is observable by the operator at all times during operation of the plant;
(c) the exhaust gas residence time within each afterburner must not be less than 0.5 seconds;
(d) propane, butane or other liquefied petroleum gas must be used as a fuel for direct infrared heating and as a combustion fuel for the afterburners;
(e) a shroud must be in place during operation of the plant, and the clearance between the lower extremity of the shroud and the road surface must not be more than 25 millimetres.
(3) If the plant uses hot air recirculation, it must comply with the following operating parameters:
(a) the temperature of each central combustion unit must be displayed so that it is observable by the operator at all times during operation of the plant;
(b) if diesel fuel is used as a fuel source, it must be No. 2 diesel fuel or a lighter distillate with a sulphur content that does not exceed 0.5% by weight.
(4) The afterburners of a direct fired infrared heating plant must be in operation at all times while pavement is being recycled.
Read the Asphalt Plant Regulation on BC Laws ↗
Made under Environmental Management Act, SBC 2003, c. 53.