Emergency Management Regulation, B.C. Reg. 217/2017
Schedule C
Schedule C
Cite as Emergency Management Regulation, B.C. Reg. 217/2017, Schedule C · last amended April 1, 2025 · read from BC Laws on November 17, 2026
The text
Schedule C
(section 7)
Pipeline Distances
Hazard planning distances for pipelines are determined by reference to the maximum potential hydrogen sulphide (H2S) release volume from the pipeline, calculated in accordance with the applicable of the following equations. The hazard planning distance for pipelines is the distance indicated on the vertical axis of Chart C that corresponds to the release volume indicated on the horizontal axis of the chart, as indicated by the graphline on the chart.
Equations
Gas pipeline H2S release volume
The equation for calculating the maximum potential H2S release volume from a pipeline is as follows: V = 2.232 x 10-6D2L(P + 101.325) HZ(T + 273) where V = maximum potential H2S release volume at standard conditions in cubic metres (m3); D = internal diameter of pipeline in millimetres (mm); L = length of pipeline between emergency shutdown valves in kilometres (km); P = licensed maximum operating pressure in kilopascals (kPa); H = licensed H2S content (moles/kilomole) for the pipeline; Z = compressibility factor at reduced pressure and reduced temperature; T = pipeline minimum operating temperature in degrees Celsius (C).
Sour liquid multiphase pipeline H2S release volume
The equation for calculating the maximum potential H2S release volume from a sour liquid multiphase pipeline is as follows: V = (GLR x GVF) x Vpl x H1 000(GLR + GVF) where V = maximum potential H2S release volume at standard conditions in cubic metres (m3); GLR = produced gas-liquid ratio at maximum operating pressure (MOP) (m3/m3); GVF = ratio of produced gas volume at standard conditions to the volume of gas at MOP (m3/m3); Vpl = volume of the pipeline in cubic metres (m3); H = licensed H2S content (moles/kilomole) for the pipeline.
Gas multiphase pipeline H2S release volume
The equation for calculating the maximum potential H2S release volume from a gas multiphase pipeline is as follows: V = 0.785 x 10-6D2L (GLR x GVF)(GLR + GVF) x H where V = maximum potential H2S release volume at standard conditions in cubic metres (m3); D = internal diameter of pipeline in millimetres (mm); L = length of pipeline between emergency shutdown valves in kilometres (km); GLR = produced gas-liquid ratio at maximum operating pressure (MOP) (m3/m3); GVF = ratio of produced gas volume at standard conditions to the volume of gas at MOP (m3/m3); H = licensed H2S content (moles/kilomole) for the pipeline.
Chart C: Pipeline Distances
Read the Emergency Management Regulation on BC Laws ↗
Made under Energy Resource Activities Act, SBC 2008, c. 36.