Energy Efficiency Standards Regulation, B.C. Reg. 14/2015

Section 16

Definitions and interpretation

Cite as Energy Efficiency Standards Regulation, B.C. Reg. 14/2015, s. 16 · last amended April 24, 2023 · read from BC Laws on November 17, 2026

The text

(1) In this Part: “ASHRAE” means the American Society of Heating, Refrigeration and Air-Conditioning Engineers; “CAN/CSA A440.2-04/A440.3-04” means CSA standard CAN/CSA A440.2-04/A440.3-04 entitled Energy Performance of Windows and Other Fenestration Systems; “CAN/CSA A440.2-09/A440.3-09” means CSA standard CAN/CSA A440.2-09/A440.3-09 entitled Fenestration energy performance; “CAN/CSA A440.2-14/A440.3-14” means CSA standard CAN/CSA A440.2-14/A440.3-14 entitled Fenestration energy performance; “CAN/CSA A440.2-19/A440.3-19” means CSA standard CAN/CSA A440.2-19/A440.3-19 entitled Fenestration energy performance; “designated heritage building” means a building that is (a) on a Provincial heritage site within the meaning of the Heritage Conservation Act or otherwise included in the Provincial heritage register under that Act, (b) protected through heritage designation or included in a community heritage register by a local government under the Local Government Act, (c) protected through heritage designation or included in the heritage register by the Council under the Vancouver Charter, or (d) protected through heritage designation or included in a community heritage register by the trust council or a local trust committee under the Islands Trust Act; “energy compliant building” means a building that (a) is not a smaller building, and (b) meets one of the following: (i) ASHRAE standard ASHRAE 90.1 (2010, 2013, 2016, 2019 or 2022) entitled Energy Standard for Buildings Except Low-Rise Residential Buildings; (ii) ASHRAE standard ASHRAE 189.1 (2014 or 2017) entitled Standard for the Design of High-Performance Green Buildings; (iii) the National Energy Code of Canada for Buildings 2011, 2015, 2017 or 2020; “larger building” means (a) a residential building that has (i) 4 or more storeys, or (ii) floor space of more than 600 m2, or (b) a non-residential building; “NFRC 100-2004” means NFRC standard NFRC 100-2004 entitled Procedure for Determining Fenestration Product U-Factors; “NFRC 100-2010” means NFRC standard NFRC 100-2010 entitled Procedure for Determining Fenestration Product U-Factors; “NFRC 100-2014” means NFRC standard NFRC 100-2014 entitled Procedure for Determining Fenestration Product U-factors; “NFRC 100-2017” means NFRC standard NFRC 100-2017 entitled Procedure for Determining Fenestration Product U-factors; “residential building” means a building with at least one residential unit; “smaller building” means a residential building that has (a) less than 4 storeys, or (b) floor space of 600 m2 or less; “U-value” means a measure of heat transfer expressed in watts per metre squared Kelvin, or W/[m2×K]. (2) Door slabs referred to in column 1 in item 1 of the efficiency standards table in section 27 [efficiency standards for manufactured fenestration products] (a) include only those door slabs that separate heated space from non-heated space, and (b) do not include door slabs referred to in section 17 [excluded door slabs]. (3) Glazing products referred to in column 1 in item 2 of the efficiency standards table in section 27 (a) include only those glazing products that (i) are for installation in door slabs, sidelites or transoms, and (ii) separate heated space from non-heated space, and (b) do not include products referred to in section 18 [excluded glazing products]. (4) Non-metal, non-wood framed windows and sliding glass doors (for smaller buildings) referred to in column 1 in items 3 and 3.1 of the efficiency standards table in section 27 (a) include only those non-metal, non-wood framed windows and sliding glass doors that (i) separate heated space from non-heated space, and (ii) are installed in smaller buildings, and (b) do not include products referred to in section 19 [excluded windows, doors, curtain walls, window walls and storefront windows (for smaller buildings)]. (5) Wood framed windows and sliding glass doors (for smaller buildings) referred to in column 1 in items 4 and 4.1 of the efficiency standards table in section 27 (a) include only those wood framed windows and sliding glass doors that (i) separate heated space from non-heated space, and (ii) are installed in smaller buildings, and (b) do not include products referred to in section 19. (5.1) Windows and sliding glass doors (for smaller buildings) referred to in column 1 in item 4.2 of the efficiency standards table in section 27 (a) include only those windows and sliding glass doors that (i) separate heated space from non-heated space, and (ii) are installed in smaller buildings, and (b) do not include products referred to in section 19. (6) Skylights referred to in column 1 in items 5 and 5.1 of the efficiency standards table in section 27 (a) include only those skylights that separate heated space from non-heated space, and (b) do not include skylights installed in an energy compliant building. (7) Metal framed curtain walls, window walls and storefront windows (for smaller buildings) referred to in column 1 in items 6, 7 and 7.1 of the efficiency standards table in section 27 (a) include only those metal framed curtain walls, window walls and storefront windows that (i) separate heated space from non-heated space, and (ii) are installed in smaller buildings, and (b) do not include products referred to in section 19. (7.1) Non-metal curtain walls, window walls and storefront windows (for smaller buildings) referred to in column 1 in item 7.2 of the efficiency standards table in section 27 (a) include only those non-metal curtain walls, window walls and storefront windows that (i) separate heated space from non-heated space, and (ii) are installed in smaller buildings, and (b) do not include products referred to in section 19. (8) Hinged and bi-folding doors (for smaller buildings) referred to in column 1 in items 8 and 8.1 of the efficiency standards table in section 27 (a) include only those hinged and bi-folding doors that (i) are fully glazed into (A) an aluminum sash construction, (B) a fibreglass sash construction, or (C) a steel sash construction, (ii) separate heated space from non-heated space, and (iii) are installed in smaller buildings, and (b) do not include products referred to in section 19. (9) Metal framed windows, sliding glass doors, curtain walls, window walls and storefront windows (for larger buildings) referred to in column 1 in item 9 of the efficiency standards table in section 27 (a) include only those metal framed windows, sliding glass doors, curtain walls, window walls and storefront windows that (i) separate heated space from non-heated space, and (ii) are installed in larger buildings, and (b) do not include products referred to in section 20 [excluded windows, doors, curtain walls, window walls and storefront windows (for larger buildings)]. (10) Non-metal windows, sliding glass doors, curtain walls, window walls and storefront windows (for larger buildings) referred to in column 1 in item 10 of the efficiency standards table in section 27 (a) include only those non-metal windows, sliding glass doors, curtain walls, window walls and storefront windows that (i) separate heated space from non-heated space, and (ii) are installed in larger buildings, and (b) do not include products referred to in section 20.
Read the Energy Efficiency Standards Regulation on BC Laws ↗

Made under Energy Efficiency Act, RSBC 1996, c. 114.