Energy Efficiency Standards Regulation, B.C. Reg. 14/2015

Section 15

Efficiency standards for compact audio products, televisions, video products and consumer battery charging systems

Cite as Energy Efficiency Standards Regulation, B.C. Reg. 14/2015, s. 15 · last amended April 24, 2023 · read from BC Laws on November 17, 2026

The text

The following efficiency standards table sets out the efficiency standards for energy devices that are compact audio products, televisions, video products and consumer battery charging systems: Item Column 1 Energy Device Column 2 Prescribed Date (s. 2 (3) (a) of Act) Column 3 Manufacturing Period Column 4 Efficiency Standard Column 5 Testing Procedure 1 Compact audio products Jan 1, 2013 Products manufactured between Jan 2, 2013 and June 1, 2018 Must be capable of entering each of the following modes that are applicable to the individual product: (a) a standby mode with a power consumption of ≤ 1 watt, with information or status display active;(b) a standby mode with a power consumption of ≤ 0.5 watts, with information or status display inactive;(c) a standby mode with a power consumption of ≤ 0.5 watts, without information or status display;(d) an off mode with a power consumption of ≤ 0.5 watts. CAN/CSA C62301-07 tested at 115 volts, regardless of the nominal voltage of the energy device 1.1 Compact audio products June 1, 2018 Products manufactured on or after June 2, 2018 Must be capable of entering each of the following modes that are applicable to the individual product: (a) a standby mode with a power consumption of ≤ 1 watt, with information or status display active;(b) a standby mode with a power consumption of ≤ 0.5 watts, with information or status display inactive;(c) a standby mode with a power consumption of ≤ 0.5 watts, without information or status display;(d) an off mode with a power consumption of ≤ 0.5 watts. CAN/CSA C62301-11, tested at 115 volts, regardless of the nominal voltage of the energy device 2 Televisions Jan 1, 2013 Products manufactured between Jan 2, 2013 and June 1, 2018 Must be capable of entering each of the following modes that are applicable to the individual product: (a) a standby mode with a power consumption of ≤ 1 watt, with information or status display active;(b) a standby mode with a power consumption of ≤ 0.5 watts, with information or status display inactive;(c) a standby mode with a power consumption of ≤ 0.5 watts, without information or status display;(d) an off mode with a power consumption of ≤ 0.5 watts. CAN/CSA C62301-07, tested at 115 volts, regardless of the nominal voltage of the energy device 2.1 Televisions June 1, 2018 Products manufactured on or after June 2, 2018 Must be capable of entering each of the following modes that are applicable to the individual product: (a) a standby mode with a power consumption of ≤ 1 watt, with information or status display active;(b) a standby mode with a power consumption of ≤ 0.5 watts, with information or status display inactive;(c) a standby mode with a power consumption of ≤ 0.5 watts, without information or status display;(d) an off mode with a power consumption of ≤ 0.5 watts. CAN/CSA C62301-11, tested at 115 volts, regardless of the nominal voltage of the energy device 3 Video products Jan 1, 2013 Products manufactured between Jan 2, 2013 and June 1, 2018 Must be capable of entering each of the following modes that are applicable to the individual product: (a) a standby mode with a power consumption of ≤ 1 watt, with information or status display active;(b) a standby mode with a power consumption of ≤ 0.5 watts, with information or status display inactive;(c) a standby mode with a power consumption of ≤ 0.5 watts, without information or status display;(d) an off mode with a power consumption of ≤ 0.5 watts. CAN/CSA C62301-07, tested at 115 volts, regardless of the nominal voltage of the energy device 3.1 Video products June 1, 2018 Products manufactured on or after June 2, 2018 Must be capable of entering each of the following modes that are applicable to the individual product: (a) a standby mode with a power consumption of ≤ 1 watt, with information or status display active;(b) a standby mode with a power consumption of ≤ 0.5 watts, with information or status display inactive;(c) a standby mode with a power consumption of ≤ 0.5 watts, without information or status display;(d) an off mode with a power consumption of ≤ 0.5 watts. CAN/CSA C62301-11, tested at 115 volts, regardless of the nominal voltage of the energy device 4 Consumer battery charging systems with Eb ≤ 2.5 watt-hours (for exclusions, see section 12) May 31, 2015 Products manufactured between June 1, 2015 and June 12, 2018 E24 must be ≤ (16 × N) watt-hours PM + PO must be ≤ (N + 0.0021 × Eb) watt-hours CAN/CSA C381.2-14 CAN/CSA C381.2-14 5 Consumer battery charging systems with Eb > 2.5 watt-hours but ≤ 100 watt-hours (for exclusions, see section 12) May 31, 2015 Products manufactured between June 1, 2015 and June 12, 2018 E24 must be ≤ (12 × N + 1.6 × Eb) watt-hours PM + PO must be ≤ (N + 0.0021 × Eb) watt-hours CAN/CSA C381.2-14 CAN/CSA C381.2-14 6 Consumer battery charging systems with Eb > 100 watt-hours but ≤ 1 000 watt-hours (for exclusions, see section 12) May 31, 2015 Products manufactured between June 1, 2015 and June 12, 2018 E24 must be ≤ (22 × N + 1.5 × Eb) watt-hours PM + PO must be ≤ (N + 0.0021 × Eb) watt-hours CAN/CSA C381.2-14 CAN/CSA C381.2-14 7 Consumer battery charging systems with Eb > 1 000 watt-hours (for exclusions, see section 12) May 31, 2015 Products manufactured between June 1, 2015 and June 12, 2018 E24 must be ≤ (36.4 × N + 1.486 × Eb) watt-hours PM + PO must be ≤ (N + 0.0021 × Eb) watt-hours CAN/CSA C381.2-14 CAN/CSA C381.2-14 8 Consumer battery charging systems with Ebatt ≤ 5 watt-hours that are designed for use in wet environments and have inductive connections (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 UEC must be ≤ 3.04 kWh/yr C381.2-17 9 Consumer battery charging systems, other than systems referred to in item 8, with Ebatt < 100 watt-hours and battery voltage of < 4 volts (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 UEC must be ≤ 0.1440 × Ebatt + 2.95 kWh/yr C381.2-17 10 Consumer battery charging systems, other than systems referred to in item 8, with Ebatt < 100 watt-hours and battery voltage of ≥ 4 volts but ≤ 10 volts (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 When Ebatt is < 10 watt-hours, UEC must be ≤ 1.42 kWh/yr When Ebatt is ≥ 10 watt-hours, UEC must be ≤ 0.0255 × Ebatt + 1.16 kWh/yr C381.2-17 C381.2-17 11 Consumer battery charging systems, other than systems referred to in item 8, with Ebatt < 100 watt-hours and battery voltage of > 10 volts (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 UEC must be ≤ 0.11 × Ebatt + 3.18 kWh/yr C381.2-17 12 Consumer battery charging systems with Ebatt ≥ 100 watt-hours but ≤ 3 000 watt-hours and battery voltage of < 20 volts (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 UEC must be ≤ 0.0257 × Ebatt + 0.815 kWh/yr C381.2-17 13 Consumer battery charging systems with Ebatt ≥ 100 watt-hours but ≤ 3 000 watt-hours and battery voltage of ≥ 20 volts (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 UEC must be ≤ 0.0778 × Ebatt + 2.4 kWh/yr C381.2-17 14 Consumer battery charging systems with Ebatt > 3 000 watt-hours (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 UEC must be ≤ 0.0502 × Ebatt + 4.53 kWh/yr C381.2-17
Read the Energy Efficiency Standards Regulation on BC Laws ↗

Made under Energy Efficiency Act, RSBC 1996, c. 114.