Elevating Devices Safety Regulation, B.C. Reg. 101/2004
Schedule 1
Schedule
Cite as Elevating Devices Safety Regulation, B.C. Reg. 101/2004, Schedule 1 · last amended March 31, 2022 · read from BC Laws on November 17, 2026
The text
Schedule
[en. B.C. Reg. 184/2019, App. 2, s. 22.] Adopted Codes and Standards 1 In this Schedule:
“ANSI” means the American National Standards Institute;
“ASME” means the American Society of Mechanical Engineers;
“CSA” means the Canadian Standards Association. 2 For the purposes of interpretation of the codes and standards referred to in this Schedule:
“bumper boats” means an amusement ride that has boats
(a) equipped with an encircling buffer device, and
(b) designed to operate in an enclosed pool and to collide with each other;
“bumper car” means an amusement ride
(a) that has passenger carrying units equipped with an encircling buffer device and operated in an enclosed area consisting of a runway, and
(b) in which the action of passengers may cause one passenger carrying unit to collide with another;
“circular ride” means an amusement ride for which motion is primarily rotary in a fixed or variable plane from horizontal to 45° above horizontal;
“discharge area” means the lower area of a waterslide or dry slide used for discharging riders;
“dispatch area” means the area of a waterslide or dry slide that is used for dispatching riders;
“dry slide” means an amusement ride that consists of one or more inclined channels that do not contain water and on which a person slides down, with or without a pad, from a height exceeding 4 m into a discharge area;
“flume ride” means an amusement ride using water as a means of conveyance;
“kiddie automobile ride” means a ride that replicates small automobiles that can be ridden only by children;
“log flume ride” means any flume ride that uses a "log" as a passenger transporter;
“operator” means a person who
(a) has direct control over the starting, stopping or speed of an amusement ride or part of the ride, or
(b) is in charge of the entire operation of an amusement ride;
“park ride” means an amusement ride other than a travelling ride;
“rotary ride” means an amusement ride in which the passengers, by the action of centrifugal force, are maintained against the inner wall of a rotating vertical cylinder while at the same time the floor of the cylinder may be lowered away from the feet of the passengers;
“safety pin retainer” means a device which retains in place a pin joint connection;
“travelling ride” means an amusement ride that is designed for repetitious erection and dismantling;
“waterslide” means any flume ride in which a transporter is not used. 3 The following codes and standards are adopted:
(a) ASME A17.1-2016/CSA B44-16, "Safety Code for Elevators and Escalators" with the variations set out in sections 4 to 19 of this Schedule, except that
(i) sections 5.3, 5.4, 5.7, 5.8, 5.9, 7.7, 7.8, 7.9, 7.10, 7.11 and 8.11 of the Code are not adopted, and
(ii) 8.6.1.7.1, 8.6.7.3, 8.6.7.4 and 8.6.7.7 to 8.6.7.9 are not adopted;
(b) National Standard of Canada CAN/CSA-B311-02 with Update No. 1 of June 2003, "Safety Code for Manlifts";
(c) CSA B355-09, "Lifts for Persons with Physical Disabilities" with the variation set out in section 20 of this Schedule, except that
(i) Clause 5.1.2 (b) and (d) is not adopted, and
(ii) Annex B is mandatory;
(d) National Standard of Canada CAN/CSA Z98-14, "Passenger ropeways and passenger conveyors", except that
(i) Clause 4.12.4.2 is not adopted, and
(ii) Annexes A, B, C, D, E, F, G, H, I, J and K are mandatory;
(e) National Standard of Canada CAN/CSA Z185-M87 (R2001), "Safety Code for Personnel Hoists", except that Appendix A is mandatory;
(f) CSA International Z267-00, "Safety Code for Amusement Rides and Devices", except that Appendices A and C are mandatory;
(g) ASME A17.7-2007/CSA B44.7-07, "Performance-based safety code for elevators and escalators";
(h) ANSI Standard ANSI A10.22-1990 (R1998), "Safety Requirements for Rope-Guided and Workers' Hoists — American National Standard for Construction and Demolition Operations".
Safety Code for Elevators and Escalators
4 5.10.1.9.5 of ASME A17.1-2016/CSA B44-16, "Safety Code for Elevators and Escalators" is repealed and the following substituted: 5.10.1.9.5 Openings of Hoistway Doors or Gates from Landing Side. All elevators used for construction or temporary elevators shall be provided with hoistway doors and gate devices that comply with either of the following:
(a) interlocks conforming to 2.12.2;
(b) combination mechanical locks and electric contacts conforming to 2.12.3.
The mechanical locking device, when used on temporary doors, shall be self-latching.
5 8.6.1.2.1 (e) is amended by adding the following to the end of the paragraph: In no case shall maintenance intervals exceed the lesser of 3 months and the manufacturer's specified limit.
6 8.6.1.2.2 (a) is amended by adding the following to the end of the paragraph: All other wiring schematics and diagrams relevant to the elevating device shall be available with the elevating device.
7 8.6.1.4.1 (a) (3) is repealed and the following substituted: (3) Maintenance control program records shall be viewable on-site by elevator personnel in both hard copy and electronic format, in a format acceptable to a provincial safety manager, made available to that authority or the owner on request of the authority or owner and shall include, but are not limited to, the following: (a) site name and address; (b) contractor's name and licence number; (c) elevating device mechanic's name and certificate of qualification number; (d) unit number; (e) date of record; (f) a description of the maintenance task, interval, and associated requirements of Section 8.6; (g) indication of completion of maintenance task.
8 8.6.1.7 is repealed and the following substituted: 8.6.1.7 Periodic Tests. Periodic tests shall be performed as follows:
(a) category 1 tests shall be performed annually;
(b) category 3 tests shall be performed every 3 years;
(c) category 5 tests shall be performed every 5 years.
9 8.6.1.7.2 is repealed and the following substituted: 8.6.1.7.2 Periodic Test Record. A periodic test record for all periodic tests shall be kept as part of the maintenance control program record both in a log book and electronically, to be available according to the requirements of 8.6.1.4.1 (a) (3), and including all of the following:
(a) the applicable Code requirement(s) and date(s) performed;
(b) the name of the person or firm performing the test;
(c) all values recorded from periodic tests, including printed charts or graphs;
(d) if any of the alternative test methods contained in 8.6.4.20 were performed, an indication that alternative testing was utilized for the applicable requirement.
10 8.6.4.1.1 is repealed and the following substituted: 8.6.4.1.1 Suspension and compensating means shall be kept sufficiently clean so that they can be visually inspected, and suspension means shall be
(a) inspected at intervals not exceeding 12 months, and
(b) replaced if they no longer conform to the applicable requirements of ASME A17.6.
11 8.6.4.2.1 is repealed and the following substituted: 8.6.4.2.1 Governor ropes shall be
(a) kept sufficiently clean so that they can be visually inspected,
(b) inspected at intervals not exceeding 12 months, and
(c) replaced if they no longer conform to the applicable requirements of ASME A17.6.
12 8.6.4.12.1 is repealed and the following substituted: 8.6.4.12.1 Governors shall be
(a) examined at intervals not exceeding 3 months to ensure that all seals are intact, and
(b) manually operated to determine that all moving parts, including the rope-grip jaws and switches, operate freely.
13 8.6.4.13.1 is amended by adding the following to the end of the Clause: Maintenance under this section shall be at intervals not exceeding 3 months.
14 8.6.4.13.2 is repealed and the following substituted: 8.6.4.13.2 Kinetic Energy and Force Limitation for Automatic Closing, Horizontal Sliding Car and Hoistway Doors or Gates. If a power-operated horizontally sliding door is closed by momentary pressure or by automatic means, the closing kinetic energy and closing force shall be maintained to conform to 2.13.4 and 2.13.5. If a data plate conforming to 2.13.4.2.4 is not required, compliance with Appendix Z is mandatory.
15 8.6.4.19.6 is repealed and the following substituted: 8.6.4.19.6 Firefighters' Emergency Operation. Firefighters' Emergency Operation (Phase I and II) shall be tested to determine conformance with the applicable requirements. Phase I recall shall be tested by simulating individual fire alarm initiating device inputs to the elevator control, the three-position key switch at the designated landing and, where provided, the two-position switch at the building fire control station (Part 6).
16 8.6.4.20.1 (a) is amended by striking out " Tests shall be made by tripping the governor by hand at the rated speed." and substituting "Except for Type A Safeties, tests shall be made by tripping the governor by hand at the rated speed. Type A Safeties may be tested at reduced speeds.".
17 8.6.5.7 is repealed and the following substituted: 8.6.5.7 Record of Oil Usage. For systems for which part of either a cylinder or piping, or both, is not exposed for visible examination,
(a) oil levels shall be verified at each maintenance visit by the certified mechanic conducting the maintenance visit,
(b) a written record shall be kept of the quantity of hydraulic fluid added to the system and emptied from leakage collection containers and pans, and the record kept in the machine room, and
(c) when the quantity of hydraulic fluid loss cannot be accounted for, the tests specified in 8.6.5.14.1 and 8.6.5.14.2 shall be made.
18 8.6.11.1 is repealed and the following substituted: 8.6.11.1 Firefighters' Emergency Operation. All elevators provided with Firefighters' Emergency Operation shall be subjected annually, by authorized personnel, to Phase I recall by use of the key switch, and a minimum of one-floor operation on Phase II. Deficiencies shall be corrected. A record of findings shall be available to elevator personnel and the authority having jurisdiction.
19 The introductory paragraph in section 8.9 is amended by striking out " new and existing equipment" and substituting "new and altered equipment".
Lifts for Persons with Physical Disabilities
20 Clause B.2.2 of Annex B of CSA B355-09, "Lifts for Persons with Physical Disabilities" is repealed and the following substituted: B.2.2 Unless otherwise specified in this Annex, the maintenance specified in Clause B.2.1 shall be carried out at intervals no longer than 3 months.
Read the Elevating Devices Safety Regulation on BC Laws ↗
Made under Safety Standards Act, SBC 2003, c. 39.