Elevating Devices Safety Regulation, B.C. Reg. 101/2004
Section 54
Hydraulic elevating devices
Cite as Elevating Devices Safety Regulation, B.C. Reg. 101/2004, s. 54 · last amended March 31, 2022 · read from BC Laws on November 17, 2026
The text
(1) In this section, “relief valve set pressure” means set-to-open pressure, set-to-start-to-open pressure or the static pressure increasingly applied in the inlet of a relief valve installed in the hydraulic system of a hydraulic elevating device, and is the pressure
(a) at which the relief valve is set to start to open and allows only drops of hydraulic fluid to pass, and
(b) that must be exceeded in order for the relief valve to pass hydraulic fluid back to the hydraulic fluid storage tank of the hydraulic system.
(2) In respect of a hydraulic elevating device, the following requirements apply to relief valve systems:
(a) the relief valve set pressure must be the set pressure that is required to meet the maximum flow capacity and maximum relieving pressure requirements in paragraph (b);
(b) the size of the relief valve and bypass must be sufficient to pass the maximum flow capacity rated for the hydraulic pump and at the same time raise the pressure above the working pressure by no more than 50% at that pump.
(3) Two or more relief valves may be used for the purposes of subsection (2) and must be
(a) designed with a means for sealing, and
(b) sealed after being set in accordance with subsection (2) (a).
(4) Repealed. [B.C. Reg. 164/2013, Sch. s. 4.]
Read the Elevating Devices Safety Regulation on BC Laws ↗
Made under Safety Standards Act, SBC 2003, c. 39.